Urology
Volume 73, Issue 2 , Pages 241-244, February 2009

Construction-related Differences Seen in Ureteral Access Sheaths: Comparison of Reinforced Versus Nonreinforced Ureteral Access Sheaths

Department of Urology, University of Miami Miller School of Medicine, Miami, Florida

Received 5 May 2008; accepted 25 July 2008. published online 08 October 2008.

Objectives

Ureteral access sheaths (UASs) are used to facilitate ureteroscopic procedures. Difficulties with use have been reported. Manufacturers have redesigned these devices to ameliorate these problems, including reinforcement of the sheath wall. This study compared reinforced (RUASs) and nonreinforced UASs (NRUASs) of the same manufacturer to determine whether RUASs expedite ureteroscopy and how relevant the reinforced structure is in terms of overall success.

Methods

We prospectively followed up patients undergoing ureteroscopy for urolithiasis with 1 of 2 UASs; the Applied NRUAS and the Applied RUAS. The demographics, operative parameters, and outcomes were assessed. Statistical analysis was performed.

Results

A total of 98 UASs were used in 68 male and 30 female patients (47 NRUASs and 51 RUASs). No significant differences were found between the groups in terms of demographic parameters, operative parameters, or successful sheath deployment. The overall success rate for sheath deployment was 95%. A pre-existing stent was significantly associated with successful deployment (P = .004). The sheath-specific limitations included kinking (NRUASs, 10%) and sheath angulation/deformity (RUASs, 21%). The mean follow-up time was 43.4 months; and 93.9% of the patients had radiologic follow-up. No ureteral strictures were noted.

Conclusions

No significant difference was found in the overall success rates between the use of Applied NRUASs and RUASs. The presence of a pre-existing stent was significantly associated with successful sheath deployment. Each UAS design had its own unique limitations, seen with low frequency. Successful sheath use might relate to both the sheath itself and the patient/operative parameters.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0090-4295(08)01424-6

doi:10.1016/j.urology.2008.07.055

Urology
Volume 73, Issue 2 , Pages 241-244, February 2009